XRY-1C Automatic Oxygen Bomb Calorimeter

简要描述: The instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672 Oxygen Bomb Calorimeter, as well as Shanghai enterprise standardQ/VCZK 10 XRY Series Oxygen Bomb Calorimeter.

产品介绍


Summary

The instrument is designed and made as per the National Standard of People’s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration Regulation of People’s Republic of China JJG672 Oxygen Bomb Calorimeter, as well as Shanghai enterprise standardQ/VCZK 10 XRY Series Oxygen Bomb Calorimeter.

 

I. Main technical features

1. Adopting semiconductor refrigeration to decide the refrigerating capacity according to the calorific value,the instrument can automatically adjust water temperature and keep water in a relative constant temperature range,realize the continuously and long time test requirement,and make sure the test result is correct.

2. With a electronic measuring cup itself,no need to weigh the water by manual,it can measure the water volume automatically,the repetitive error0.4g

3. Automatically detecting the resistance of ignition filament,automatically checking the installing condition of ignition filament before test.

4. Standard pipeline design,vastly shortening the pipeline,and more reasonable pipeline design to ensure more precision of test results.

5. Adopting professional discharge water ports,more convenient and fast when the  instrument drains away water or change the water.

6. The electronic balance with communication function to share the data by the internet.

 

II. Main technical specifications

1. Power supplyAC (220±10%)V, 50 Hz

2. Total power consumption≤0.2kW

3. Measuring temperature range5℃35℃

4. Temperature resolution0.0001℃

5. RSD(Relative standard deviation)≤40J/K

6. Test time periodmain periodabout 12 min

7. Heat capacity (900011000)J/K

8. Measuring error±60J/g Benzoic acid

9. Accuracy:Better than GB/T213-2008 “ The determination method of coal calorific value“

10. Pressure endurance of oxygen bomb: 20 MPa

11. Suitable environment

Ambient temp.(1528)℃, Continuous repeated testing, with an environmental temperature change of ≤ 2 ℃;

Relative humidity: ≤85%

12. Outline dimension650mm×450mm×450mmL×W×H

13. Net weight: 55kg